daemon: Fix shutdown on boot on some machines
On the Lenovo A600 all-in-one, there's a HCI/HID dual-mode Broadcom device which will try to get the battery level of the supplied mouse and keyboard, but will usually fail to do so. So we have a battery of type "battery" (it's not either a mouse or a keyboard, as it's supposed to handle both) but our display device battery code doesn't check whether those batteries are power supplies or not, using this "empty" (0% after the check timed out) battery in the shutdown policy. Check better for power supply devices, not all the "battery" types are power supply batteries, they might be non-power supply ones from unknown device types.
This commit is contained in:
parent
d650df8af8
commit
dbf7eb7e55
1 changed files with 10 additions and 3 deletions
|
|
@ -208,6 +208,7 @@ up_daemon_update_display_battery (UpDaemon *daemon)
|
|||
gdouble energy_rate = 0.0;
|
||||
gint64 time_to_empty = 0;
|
||||
gint64 time_to_full = 0;
|
||||
gboolean power_supply = FALSE;
|
||||
|
||||
device = g_ptr_array_index (array, i);
|
||||
g_object_get (device,
|
||||
|
|
@ -219,6 +220,7 @@ up_daemon_update_display_battery (UpDaemon *daemon)
|
|||
"energy-rate", &energy_rate,
|
||||
"time-to-empty", &time_to_empty,
|
||||
"time-to-full", &time_to_full,
|
||||
"power-supply", &power_supply,
|
||||
NULL);
|
||||
|
||||
/* When we have a UPS, it's either a desktop, and
|
||||
|
|
@ -236,7 +238,8 @@ up_daemon_update_display_battery (UpDaemon *daemon)
|
|||
is_present_total = TRUE;
|
||||
break;
|
||||
}
|
||||
if (kind != UP_DEVICE_KIND_BATTERY)
|
||||
if (kind != UP_DEVICE_KIND_BATTERY ||
|
||||
power_supply == FALSE)
|
||||
continue;
|
||||
|
||||
/* If one battery is charging, then the composite is charging
|
||||
|
|
@ -389,17 +392,21 @@ up_daemon_refresh_battery_devices (UpDaemon *daemon)
|
|||
guint i;
|
||||
GPtrArray *array;
|
||||
UpDevice *device;
|
||||
UpDeviceKind type;
|
||||
|
||||
/* refresh all devices in array */
|
||||
array = up_device_list_get_array (daemon->priv->power_devices);
|
||||
for (i=0; i<array->len; i++) {
|
||||
UpDeviceKind type;
|
||||
gboolean power_supply;
|
||||
|
||||
device = (UpDevice *) g_ptr_array_index (array, i);
|
||||
/* only refresh battery devices */
|
||||
g_object_get (device,
|
||||
"type", &type,
|
||||
"power-supply", &power_supply,
|
||||
NULL);
|
||||
if (type == UP_DEVICE_KIND_BATTERY)
|
||||
if (type == UP_DEVICE_KIND_BATTERY &&
|
||||
power_supply)
|
||||
up_device_refresh_internal (device);
|
||||
}
|
||||
g_ptr_array_unref (array);
|
||||
|
|
|
|||
Loading…