mirror of
https://gitlab.freedesktop.org/upower/upower.git
synced 2025-12-20 02:00:03 +01:00
up-daemon: Report UP_DEVICE_LEVEL_NONE when battery is performing recalibration
If the battery is performing recalibration and AC is online, UP_DEVICE_LEVEL_NONE is considered.
This commit is contained in:
parent
4722fcfaac
commit
d9f42cfc9d
1 changed files with 17 additions and 0 deletions
|
|
@ -769,6 +769,8 @@ up_daemon_compute_warning_level (UpDaemon *daemon,
|
|||
gdouble percentage,
|
||||
gint64 time_to_empty)
|
||||
{
|
||||
gboolean can_risky = FALSE;
|
||||
gboolean expect_battery_recalibration = FALSE;
|
||||
gboolean use_percentage = TRUE;
|
||||
UpDeviceLevel default_level = UP_DEVICE_LEVEL_NONE;
|
||||
|
||||
|
|
@ -791,6 +793,21 @@ up_daemon_compute_warning_level (UpDaemon *daemon,
|
|||
default_level = UP_DEVICE_LEVEL_DISCHARGING;
|
||||
}
|
||||
|
||||
/* Check if the battery is performing the battery recalibration and
|
||||
* AC is online, the battery level is UP_DEVICE_LEVEL_NONE. */
|
||||
can_risky = up_config_get_boolean (daemon->priv->config,
|
||||
"AllowRiskyCriticalPowerAction");
|
||||
expect_battery_recalibration = up_config_get_boolean (daemon->priv->config,
|
||||
"ExpectBatteryRecalibration");
|
||||
|
||||
if (can_risky && kind == UP_DEVICE_KIND_BATTERY) {
|
||||
if (expect_battery_recalibration &&
|
||||
up_daemon_get_on_ac_local (daemon, NULL)) {
|
||||
g_debug ("ExpectBatteryRecalibration is enabled and the AC is connected, so the battery level is not critical");
|
||||
return UP_DEVICE_LEVEL_NONE;
|
||||
}
|
||||
}
|
||||
|
||||
if (power_supply &&
|
||||
!daemon->priv->use_percentage_for_policy &&
|
||||
time_to_empty > 0.0)
|
||||
|
|
|
|||