mirror of
https://gitlab.freedesktop.org/upower/upower.git
synced 2025-12-20 04:20:04 +01:00
all: Remove WarningLevel from the daemon properties
The WarningLevel property just replicated the warning level on the display device, or at least should have. So we fix the latter to remove the former.
This commit is contained in:
parent
c00eda8ca0
commit
b2f72dd69a
5 changed files with 1 additions and 61 deletions
|
|
@ -69,7 +69,6 @@ enum {
|
|||
PROP_0,
|
||||
PROP_DAEMON_VERSION,
|
||||
PROP_ON_BATTERY,
|
||||
PROP_WARNING_LEVEL,
|
||||
PROP_LID_IS_CLOSED,
|
||||
PROP_LID_IS_PRESENT,
|
||||
PROP_IS_DOCKED,
|
||||
|
|
@ -230,23 +229,6 @@ up_client_get_on_battery (UpClient *client)
|
|||
return up_client_glue_get_on_battery (client->priv->proxy);
|
||||
}
|
||||
|
||||
/**
|
||||
* up_client_get_warning_level:
|
||||
* @client: a #UpClient instance.
|
||||
*
|
||||
* Get whether the system is low on battery, or critically low.
|
||||
*
|
||||
* Return value: The #UpDeviceLevel of the whole system.
|
||||
*
|
||||
* Since: 1.0
|
||||
**/
|
||||
UpDeviceLevel
|
||||
up_client_get_warning_level (UpClient *client)
|
||||
{
|
||||
g_return_val_if_fail (UP_IS_CLIENT (client), FALSE);
|
||||
return up_client_glue_get_warning_level (client->priv->proxy);
|
||||
}
|
||||
|
||||
/*
|
||||
* up_client_add:
|
||||
*/
|
||||
|
|
@ -351,9 +333,6 @@ up_client_get_property (GObject *object,
|
|||
case PROP_ON_BATTERY:
|
||||
g_value_set_boolean (value, up_client_glue_get_on_battery (client->priv->proxy));
|
||||
break;
|
||||
case PROP_WARNING_LEVEL:
|
||||
g_value_set_uint (value, up_client_glue_get_warning_level (client->priv->proxy));
|
||||
break;
|
||||
case PROP_LID_IS_CLOSED:
|
||||
g_value_set_boolean (value, up_client_glue_get_lid_is_closed (client->priv->proxy));
|
||||
break;
|
||||
|
|
@ -409,21 +388,6 @@ up_client_class_init (UpClientClass *klass)
|
|||
NULL,
|
||||
FALSE,
|
||||
G_PARAM_READABLE));
|
||||
/**
|
||||
* UpClient:warning-level:
|
||||
*
|
||||
* The warning level e.g. %UP_DEVICE_LEVEL_WARNING.
|
||||
*
|
||||
* Since: 1.0
|
||||
**/
|
||||
g_object_class_install_property (object_class,
|
||||
PROP_WARNING_LEVEL,
|
||||
g_param_spec_uint ("warning-level",
|
||||
NULL, NULL,
|
||||
UP_DEVICE_LEVEL_UNKNOWN,
|
||||
UP_DEVICE_LEVEL_LAST,
|
||||
UP_DEVICE_LEVEL_UNKNOWN,
|
||||
G_PARAM_READABLE));
|
||||
/**
|
||||
* UpClient:lid-is-closed:
|
||||
*
|
||||
|
|
|
|||
|
|
@ -89,7 +89,6 @@ gboolean up_client_get_lid_is_closed (UpClient *client);
|
|||
gboolean up_client_get_lid_is_present (UpClient *client);
|
||||
gboolean up_client_get_is_docked (UpClient *client);
|
||||
gboolean up_client_get_on_battery (UpClient *client);
|
||||
UpDeviceLevel up_client_get_warning_level (UpClient *client);
|
||||
|
||||
G_END_DECLS
|
||||
|
||||
|
|
|
|||
|
|
@ -180,13 +180,6 @@ method return sender=:1.386 -> dest=:1.451 reply_serial=2
|
|||
</doc:para></doc:description></doc:doc>
|
||||
</property>
|
||||
|
||||
<property name="WarningLevel" type="u" access="read">
|
||||
<doc:doc><doc:description><doc:para>
|
||||
Indicates whether the system is running on battery power and if the batteries are low,
|
||||
or critically low. This property is provided for convenience.
|
||||
</doc:para></doc:description></doc:doc>
|
||||
</property>
|
||||
|
||||
<property name="LidIsClosed" type="b" access="read">
|
||||
<doc:doc>
|
||||
<doc:description>
|
||||
|
|
|
|||
|
|
@ -50,7 +50,6 @@ enum
|
|||
PROP_LID_IS_CLOSED,
|
||||
PROP_LID_IS_PRESENT,
|
||||
PROP_IS_DOCKED,
|
||||
PROP_WARNING_LEVEL,
|
||||
PROP_LAST
|
||||
};
|
||||
|
||||
|
|
@ -758,9 +757,8 @@ up_daemon_set_warning_level (UpDaemon *daemon, UpDeviceLevel warning_level)
|
|||
|
||||
g_debug ("warning_level = %s", up_device_level_to_string (warning_level));
|
||||
priv->warning_level = warning_level;
|
||||
g_object_notify (G_OBJECT (daemon), "warning-level");
|
||||
|
||||
up_daemon_queue_changed_property (daemon, "WarningLevel", g_variant_new_uint32 (warning_level));
|
||||
g_object_set (G_OBJECT (daemon->priv->display_device), "warning-level", warning_level, NULL);
|
||||
|
||||
if (daemon->priv->warning_level == UP_DEVICE_LEVEL_ACTION) {
|
||||
if (daemon->priv->action_timeout_id == 0) {
|
||||
|
|
@ -1121,9 +1119,6 @@ up_daemon_get_property (GObject *object, guint prop_id, GValue *value, GParamSpe
|
|||
case PROP_IS_DOCKED:
|
||||
g_value_set_boolean (value, priv->is_docked);
|
||||
break;
|
||||
case PROP_WARNING_LEVEL:
|
||||
g_value_set_uint (value, priv->warning_level);
|
||||
break;
|
||||
default:
|
||||
G_OBJECT_WARN_INVALID_PROPERTY_ID (object, prop_id, pspec);
|
||||
break;
|
||||
|
|
@ -1206,15 +1201,6 @@ up_daemon_class_init (UpDaemonClass *klass)
|
|||
FALSE,
|
||||
G_PARAM_READABLE));
|
||||
|
||||
g_object_class_install_property (object_class,
|
||||
PROP_WARNING_LEVEL,
|
||||
g_param_spec_uint ("warning-level",
|
||||
NULL, NULL,
|
||||
UP_DEVICE_LEVEL_UNKNOWN,
|
||||
UP_DEVICE_LEVEL_LAST,
|
||||
UP_DEVICE_LEVEL_UNKNOWN,
|
||||
G_PARAM_READABLE));
|
||||
|
||||
g_object_class_install_property (object_class,
|
||||
PROP_LID_IS_CLOSED,
|
||||
g_param_spec_boolean ("lid-is-closed",
|
||||
|
|
|
|||
|
|
@ -128,7 +128,6 @@ up_client_print (UpClient *client)
|
|||
g_object_get (client,
|
||||
"daemon-version", &daemon_version,
|
||||
"on-battery", &on_battery,
|
||||
"warning-level", &warning_level,
|
||||
"lid-is-closed", &lid_is_closed,
|
||||
"lid-is-present", &lid_is_present,
|
||||
"is-docked", &is_docked,
|
||||
|
|
@ -136,7 +135,6 @@ up_client_print (UpClient *client)
|
|||
|
||||
g_print (" daemon-version: %s\n", daemon_version);
|
||||
g_print (" on-battery: %s\n", on_battery ? "yes" : "no");
|
||||
g_print (" warning-level: %s\n", up_device_level_to_string (warning_level));
|
||||
g_print (" lid-is-closed: %s\n", lid_is_closed ? "yes" : "no");
|
||||
g_print (" lid-is-present: %s\n", lid_is_present ? "yes" : "no");
|
||||
g_print (" is-docked: %s\n", is_docked ? "yes" : "no");
|
||||
|
|
|
|||
Loading…
Add table