linux: up-device-supply-battery: Using charge_types Long_Life and Standard to manage charging threshold
We found some systems, such as Lenovo ideapad that don't support charge_control_start_threshold and charge_control_end_threshold but it provide the charge_types Long_Life and Standard. The chatre_types Long_Life operate the battery in the conservation mode. That means if Long_Life and Standard are found, the system supports the charge threshold feature. Co-work-with: Cursor Reviewed-by: Kate Hsuan <hpa@redhat.com>
This commit is contained in:
parent
0e6493ce22
commit
a97c3ceaf5
1 changed files with 50 additions and 3 deletions
|
|
@ -69,6 +69,7 @@ struct _UpDeviceSupplyBattery
|
|||
gdouble rate_old;
|
||||
guint supported_charge_types;
|
||||
UpDeviceSupplyBatteryChargeTypes charge_type;
|
||||
gboolean charge_threshold_by_charge_type;
|
||||
gboolean shown_invalid_voltage_warning;
|
||||
gboolean ignore_system_percentage;
|
||||
};
|
||||
|
|
@ -328,6 +329,41 @@ up_device_battery_get_supported_charge_types (UpDevice *device)
|
|||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* up_device_supply_battery_is_charge_threshold_by_charge_type:
|
||||
* @device: the device to check
|
||||
*
|
||||
* Return %TRUE if the charge threshold is controlled by charge_types,
|
||||
* %FALSE otherwise.
|
||||
*
|
||||
* Co-work-with: Cursor
|
||||
* Reviewed-by: Kate Hsuan <hpa@redhat.com>
|
||||
*/
|
||||
static gboolean
|
||||
up_device_supply_battery_is_charge_threshold_by_charge_type (UpDevice *device) {
|
||||
GUdevDevice *native = NULL;
|
||||
UpDeviceSupplyBattery *self = UP_DEVICE_SUPPLY_BATTERY (device);
|
||||
|
||||
native = G_UDEV_DEVICE (up_device_get_native (device));
|
||||
|
||||
/* if the charge_control_start_threshold or charge_control_end_threshold is found,
|
||||
* then the charge threshold is not controlled by charge_types. */
|
||||
if (g_udev_device_has_sysfs_attr (native, "charge_control_start_threshold") ||
|
||||
g_udev_device_has_sysfs_attr (native, "charge_control_end_threshold"))
|
||||
return FALSE;
|
||||
|
||||
if (self->supported_charge_types & UP_DEVICE_SUPPLY_BATTERY_CHARGE_TYPES_LONG_LIFE) {
|
||||
if (self->supported_charge_types & (UP_DEVICE_SUPPLY_BATTERY_CHARGE_TYPES_STANDARD |
|
||||
UP_DEVICE_SUPPLY_BATTERY_CHARGE_TYPES_ADAPTIVE |
|
||||
UP_DEVICE_SUPPLY_BATTERY_CHARGE_TYPES_FAST)) {
|
||||
g_debug ("charge_control_start_threshold and charge_control_end_threshold are not found but the supported charge_types Long_lift, Standard or Adaptive was found. Assuming charging threshold is supported");
|
||||
return TRUE;
|
||||
}
|
||||
}
|
||||
|
||||
return FALSE;
|
||||
}
|
||||
|
||||
static gboolean
|
||||
up_device_supply_battery_refresh (UpDevice *device,
|
||||
UpRefreshReason reason)
|
||||
|
|
@ -394,6 +430,20 @@ up_device_supply_battery_refresh (UpDevice *device,
|
|||
info.charge_control_supported = FALSE;
|
||||
}
|
||||
|
||||
/* refresh the changes of charge_types */
|
||||
up_device_battery_get_supported_charge_types (device);
|
||||
|
||||
/* Test charge_types attribute, if "Long_Life", "Standard", "Adaptive" or "Fast" are found,
|
||||
* then set charge_control_supported to TRUE.
|
||||
*
|
||||
* Co-work-with: Cursor
|
||||
* Reviewed-by: Kate Hsuan <hpa@redhat.com> */
|
||||
if (up_device_supply_battery_is_charge_threshold_by_charge_type (device)) {
|
||||
g_debug ("charge_types attribute is found, set charge_control_supported to TRUE");
|
||||
info.charge_control_supported = TRUE;
|
||||
self->charge_threshold_by_charge_type = TRUE;
|
||||
}
|
||||
|
||||
/* NOTE: We used to warn about full > design, but really that is perfectly fine to happen. */
|
||||
|
||||
/* Update the battery information (will only fire events for actual changes) */
|
||||
|
|
@ -462,9 +512,6 @@ up_device_supply_battery_refresh (UpDevice *device,
|
|||
|
||||
values.temperature = g_udev_device_get_sysfs_attr_as_double_uncached (native, "temp") / 10.0;
|
||||
|
||||
/* refresh the changes of charge_types */
|
||||
up_device_battery_get_supported_charge_types (device);
|
||||
|
||||