daemon: Fix critical action after resume from hibernate
The take_action_timeout_cb() function returns G_SOURCE_REMOVE which makes GLib destroy the timeout. However the action_timeout_id stayed != 0 so when warning level turned to "action" again the daemon assumed that the timeout is already set and did nothing. (It only logged: "Not taking action, timeout id already set") https://bugs.freedesktop.org/show_bug.cgi?id=87791
This commit is contained in:
parent
b69b262230
commit
212599f0ee
2 changed files with 65 additions and 1 deletions
|
|
@ -249,8 +249,11 @@ class Tests(dbusmock.DBusTestCase):
|
|||
stdout=subprocess.PIPE)
|
||||
|
||||
def have_text_in_log(self, text):
|
||||
return self.count_text_in_log(text) > 0
|
||||
|
||||
def count_text_in_log(self, text):
|
||||
with open(self.log.name) as f:
|
||||
return text in f.read()
|
||||
return f.read().count(text)
|
||||
|
||||
def assertEventually(self, condition, message=None, timeout=50):
|
||||
'''Assert that condition function eventually returns True.
|
||||
|
|
@ -760,6 +763,63 @@ class Tests(dbusmock.DBusTestCase):
|
|||
|
||||
self.stop_daemon()
|
||||
|
||||
def test_critical_action_is_taken_repeatedly(self):
|
||||
'''check that critical action works repeatedly (eg. after resume)'''
|
||||
|
||||
bat0 = self.testbed.add_device('power_supply', 'BAT0', None,
|
||||
['type', 'Battery',
|
||||
'present', '1',
|
||||
'status', 'Discharging',
|
||||
'energy_full', '60000000',
|
||||
'energy_full_design', '80000000',
|
||||
'energy_now', '50000000',
|
||||
'voltage_now', '12000000'], [])
|
||||
|
||||
config = tempfile.NamedTemporaryFile(delete=False, mode='w')
|
||||
config.write("[UPower]\n")
|
||||
config.write("UsePercentageForPolicy=true\n")
|
||||
config.write("PercentageAction=5\n")
|
||||
config.write("CriticalPowerAction=Hibernate\n")
|
||||
config.close()
|
||||
|
||||
self.start_logind()
|
||||
self.start_daemon(cfgfile=config.name)
|
||||
|
||||
devs = self.proxy.EnumerateDevices()
|
||||
self.assertEqual(len(devs), 1)
|
||||
bat0_up = devs[0]
|
||||
|
||||
# simulate that battery has 1% (less than PercentageAction)
|
||||
self.testbed.set_attribute(bat0, 'energy_now', '600000')
|
||||
self.testbed.uevent(bat0, 'change')
|
||||
|
||||
time.sleep(0.5)
|
||||
self.assertEqual(self.get_dbus_display_property('WarningLevel'), UP_DEVICE_LEVEL_ACTION)
|
||||
|
||||
time.sleep(20.5) # wait for UP_DAEMON_ACTION_DELAY
|
||||
self.assertEqual(self.count_text_in_log("About to call logind method Hibernate"), 1)
|
||||
|
||||
# simulate that battery was charged to 100% during sleep
|
||||
self.testbed.set_attribute(bat0, 'energy_now', '60000000')
|
||||
self.testbed.uevent(bat0, 'change')
|
||||
|
||||
time.sleep(0.5)
|
||||
self.assertEqual(self.get_dbus_display_property('WarningLevel'), UP_DEVICE_LEVEL_NONE)
|
||||
|
||||
# simulate that battery was drained to 1% again
|
||||
self.testbed.set_attribute(bat0, 'energy_now', '600000')
|
||||
self.testbed.uevent(bat0, 'change')
|
||||
|
||||
time.sleep(0.5)
|
||||
self.assertEqual(self.get_dbus_display_property('WarningLevel'), UP_DEVICE_LEVEL_ACTION)
|
||||
|
||||
time.sleep(20.5) # wait for UP_DAEMON_ACTION_DELAY
|
||||
self.assertEqual(self.count_text_in_log("About to call logind method Hibernate"), 2)
|
||||
|
||||
self.stop_daemon()
|
||||
|
||||
os.unlink(config.name)
|
||||
|
||||
def test_no_poll_batteries(self):
|
||||
''' setting NoPollBatteries option should disable polling'''
|
||||
|
||||
|
|
|
|||
|
|
@ -587,6 +587,10 @@ static gboolean
|
|||
take_action_timeout_cb (UpDaemon *daemon)
|
||||
{
|
||||
up_backend_take_action (daemon->priv->backend);
|
||||
|
||||
g_debug ("Backend was notified to take action. The timeout will be removed.");
|
||||
daemon->priv->action_timeout_id = 0;
|
||||
|
||||
return G_SOURCE_REMOVE;
|
||||
}
|
||||
|
||||
|
|
|
|||
Loading…