mirror of
https://gitlab.freedesktop.org/mesa/mesa.git
synced 2026-05-03 09:58:05 +02:00
zink: compare against screen batch id when determining which semaphore to use
semaphores are per-screen now, so check the screen value
Fixes: fa36a16c68 ("zink: make timeline semaphores per-screen")
Reviewed-by: Adam Jackson <ajax@redhat.com>
Part-of: <https://gitlab.freedesktop.org/mesa/mesa/-/merge_requests/10267>
This commit is contained in:
parent
20e2c7308f
commit
5b9c3cb7b9
1 changed files with 1 additions and 1 deletions
|
|
@ -1956,7 +1956,7 @@ timeline_wait(struct zink_context *ctx, uint32_t batch_id, uint64_t timeout)
|
|||
wi.sType = VK_STRUCTURE_TYPE_SEMAPHORE_WAIT_INFO;
|
||||
wi.semaphoreCount = 1;
|
||||
/* handle batch_id overflow */
|
||||
wi.pSemaphores = batch_id > ctx->curr_batch ? &screen->prev_sem : &screen->sem;
|
||||
wi.pSemaphores = batch_id > screen->curr_batch ? &screen->prev_sem : &screen->sem;
|
||||
uint64_t batch_id64 = batch_id;
|
||||
wi.pValues = &batch_id64;
|
||||
bool success = false;
|
||||
|
|
|
|||