In Linux envrionment, signal.h included by sys/wait.h, however, this
isn't the case in FreeBSD. So explicit include it to fix build failure.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=66197
Signed-off-by: Chengwei Yang <chengwei.yang@intel.com>
Reviewed-by: Simon McVittie <simon.mcvittie@collabora.co.uk>
This commit does several more strictly check for dbus-send as its usage
suggested.
* now --address is an invalid option but --address=, this just like the
others, say --reply-timeout=, --dest=, --type=
* --print-reply= only take an optional argument "=literal"
* --print-reply= will cause error with missing MSEC and invalid MSEC
will cause invalid value error
* --dest= will cause error with missing a NAME and also call
dbus_validate_bus_name to verify the NAME
Signed-off-by: Chengwei Yang <chengwei.yang@intel.com>
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=65424
Reviewed-by: Simon McVittie <simon.mcvittie@collabora.co.uk>
It turns out that if you don't second-guess the system by catching
SIGINT, the right things happen: it's received by every program in the
foreground process group, including dbus-run-session and dbus-daemon.
Neither of those catch SIGINT (unlike dbus-launch) so they'll exit
gracefully without the wrapper script needing to do anything special.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=39196
Reviewed-by: Colin Walters <walters@verbum.org>
From the department of "if it isn't tested, it doesn't work". I tried
compiling dbus without an assortment of optional features:
in_builddir ~/build/dbus/legacy ${MR_REPO}/configure \
--enable-developer --enable-maintainer-mode --enable-tests \
dbus_cv_sync_sub_and_fetch=no \
--disable-selinux \
--disable-inotify \
--disable-dnotify \
--disable-epoll \
--disable-kqueue \
--disable-launchd \
--disable-systemd \
--disable-libaudit \
--without-valgrind \
--disable-x11-autolaunch \
&& ...
and it resulted in -Wunused warnings.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=64362
Signed-off-by: Simon McVittie <simon.mcvittie@collabora.co.uk>
Reviewed-by: Thiago Macieira <thiago@kde.org>
...except for CheckForAbstractSockets.c, which runs before config.h is
generated, and sd-daemon.c, which is externally-maintained.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=59971
Signed-off-by: Simon McVittie <simon.mcvittie@collabora.co.uk>
Reviewed-by: Colin Walters <walters@verbum.org>
If dbus is installed in a path, which contains a space, dbus-launch will
not launch the daemon. That is so, because a command line is built from
just the path to the daemon and a parameter. The path has to be
surrounded with quotes. This can be done unconditionally, because the
quotes do not cause any trouble even if they are not needed.
Reviewed-by: Ralf Habacker <ralf.habacker@freenet.de>
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=49450
Since Automake 1.11.4, an empty localstatelib_DATA variable will not
create $(localstatelibdir) as a side-effect.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=51406
Signed-off-by: Simon McVittie <simon.mcvittie@collabora.co.uk>
Reviewed-by: Lennart Poettering <lennart@poettering.net>
When targeting Windows, linking against the static library requires
special effort to turn off DLL import/export processing. We normally
link some things against the dynamic library, but if we're not building
that, we'll have to link everything statically.
Based on patches from 'william' on fd.o #46367.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=33973
Tested-by: René Berber <Rene.Berber gmail com>
This is more suitable for distributions' Xsession scripts: it verifies
that X is already available, and so never results in an attempt to poll
stdin.
Reviewed-by: Will Thompson <will.thompson@collabora.co.uk>
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=39197
dbus-launch --exit-with-session attempts to scope the session length
to various things:
- if DISPLAY points to an X server, exit when the X session ends
- if stdin is a terminal, exit when end-of-file is reached
- if both are true, exit when one of them happens, whichever is first
- if neither is true, fail
These are not particularly useful semantics: if the session is scoped to
the X session, then the terminal from which dbus-launch was launched
is irrelevant. This also causes practical problems when dbus-launch
consumes characters from the terminal from which it happens to have
been launched (some display managers, like slim and nodm, run users' X
sessions with stdin pointing to the terminal from which the init daemon
happens to have started the display manager during boot, usually tty1
on Linux).
Reviewed-by: Will Thompson <will.thompson@collabora.co.uk>
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=39197
* dbus-send, dbus-uuidgen only need to link libdbus; libtool knows what
extra libraries libdbus depends on
* dbus-monitor uses a Winsock header (on Windows) so it needs
NETWORK_libs,but still doesn't need threads
* dbus-launch needs X (on Unix) but doesn't directly need threads or
networking
DBUS_ENABLE_X11_AUTOLAUNCH obviously requires DBUS_BUILD_X11. However,
the converse is not true.
If DBUS_BUILD_X11 is defined, dbus-launch will be able to connect to
the X server to determine when the session ends; most distributors will
want this, but it can be disabled with the standard Autoconf option
--without-x.
If DBUS_ENABLE_X11_AUTOLAUNCH is *also* defined, dbus-launch and libdbus
will be willing to perform autolaunch. Again, most distributors will want
this, but it can be disabled with --disable-x11-autolaunch.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=19997
Reviewed-by: Colin Walters <walters@verbum.org>
This doesn't really do anything, because we're about to exit anyway, but
it placates static analysis tools.
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=29881
Bug-NB: NB#180486
Reviewed-by: Cosimo Alfarano <cosimo.alfarano@collabora.co.uk>
A coworker was just tripped up by `dbus-monitor --session --system` only
monitoring the system bus. This patch would have saved him reproducing a
tricky bug several times!
Bug: https://bugs.freedesktop.org/show_bug.cgi?id=26548
Reviewed-by: Colin Walters <walters@verbum.org>
Reviewed-by: Simon McVittie <simon.mcvittie@collabora.co.uk>
This will make integrating the building of HTML versions of these
manpages into the build system way easier, at the cost of keeping
manpages in a different directory to the source for the program they
describe. I think this is an acceptable trade-off.