2020-12-23 22:21:36 +01:00
|
|
|
/* SPDX-License-Identifier: GPL-2.0-or-later */
|
2019-09-25 13:13:40 +02:00
|
|
|
/*
|
2019-10-01 09:20:35 +02:00
|
|
|
* Copyright (C) 2016 Atul Anand <atulhjp@gmail.com>.
|
2016-08-16 05:55:57 +05:30
|
|
|
*/
|
|
|
|
|
|
2021-02-04 18:04:13 +01:00
|
|
|
#include "src/core/nm-default-daemon.h"
|
2016-08-16 05:55:57 +05:30
|
|
|
|
|
|
|
|
#include "nm-pacrunner-manager.h"
|
|
|
|
|
|
2018-04-06 16:40:23 +02:00
|
|
|
#include "c-list/src/c-list.h"
|
2021-02-18 17:37:47 +01:00
|
|
|
#include "libnm-glib-aux/nm-dbus-aux.h"
|
2021-08-06 15:17:05 +02:00
|
|
|
#include "libnm-platform/nm-platform.h"
|
|
|
|
|
|
|
|
|
|
#include "NetworkManagerUtils.h"
|
|
|
|
|
#include "nm-dbus-manager.h"
|
|
|
|
|
#include "nm-l3-config-data.h"
|
|
|
|
|
#include "nm-utils.h"
|
2017-03-08 14:56:17 +01:00
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
#define PACRUNNER_DBUS_SERVICE "org.pacrunner"
|
|
|
|
|
#define PACRUNNER_DBUS_INTERFACE "org.pacrunner.Manager"
|
|
|
|
|
#define PACRUNNER_DBUS_PATH "/org/pacrunner/manager"
|
|
|
|
|
|
2016-10-04 11:58:32 +02:00
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
struct _NMPacrunnerConfId {
|
|
|
|
|
CList conf_id_lst;
|
2017-05-11 12:04:24 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
NMPacrunnerManager *self;
|
|
|
|
|
|
|
|
|
|
GVariant *parameters;
|
2017-05-11 12:04:24 +02:00
|
|
|
|
2021-11-09 13:28:54 +01:00
|
|
|
char *path;
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
guint64 log_id;
|
2017-03-08 14:56:17 +01:00
|
|
|
guint refcount;
|
2017-04-21 15:46:56 +02:00
|
|
|
};
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
typedef struct {
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
GDBusConnection *dbus_connection;
|
2021-11-09 13:28:54 +01:00
|
|
|
GCancellable *cancellable;
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
CList conf_id_lst_head;
|
|
|
|
|
guint64 log_id_counter;
|
|
|
|
|
guint name_owner_changed_id;
|
|
|
|
|
bool dbus_initied : 1;
|
|
|
|
|
bool has_name_owner : 1;
|
|
|
|
|
bool try_start_blocked : 1;
|
2016-10-04 12:13:16 +02:00
|
|
|
} NMPacrunnerManagerPrivate;
|
2016-08-16 05:55:57 +05:30
|
|
|
|
2016-10-04 12:13:16 +02:00
|
|
|
struct _NMPacrunnerManager {
|
2016-08-19 09:32:20 +02:00
|
|
|
GObject parent;
|
2016-10-04 12:13:16 +02:00
|
|
|
NMPacrunnerManagerPrivate _priv;
|
2016-08-19 09:32:20 +02:00
|
|
|
};
|
|
|
|
|
|
2016-10-04 12:13:16 +02:00
|
|
|
struct _NMPacrunnerManagerClass {
|
2016-08-19 09:32:20 +02:00
|
|
|
GObjectClass parent;
|
|
|
|
|
};
|
|
|
|
|
|
2016-10-04 12:13:16 +02:00
|
|
|
G_DEFINE_TYPE(NMPacrunnerManager, nm_pacrunner_manager, G_TYPE_OBJECT)
|
2016-08-19 09:32:20 +02:00
|
|
|
|
2016-10-04 12:13:16 +02:00
|
|
|
#define NM_PACRUNNER_MANAGER_GET_PRIVATE(self) \
|
|
|
|
|
_NM_GET_PRIVATE(self, NMPacrunnerManager, NM_IS_PACRUNNER_MANAGER)
|
2016-10-04 11:58:32 +02:00
|
|
|
|
|
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
2016-10-04 12:13:16 +02:00
|
|
|
NM_DEFINE_SINGLETON_GETTER(NMPacrunnerManager, nm_pacrunner_manager_get, NM_TYPE_PACRUNNER_MANAGER);
|
2016-08-19 09:32:20 +02:00
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
2016-10-14 15:32:56 +02:00
|
|
|
#define _NMLOG_DOMAIN LOGD_PROXY
|
2017-03-09 14:45:45 +01:00
|
|
|
#define _NMLOG(level, ...) __NMLOG_DEFAULT(level, _NMLOG_DOMAIN, "pacrunner", __VA_ARGS__)
|
2016-08-16 05:55:57 +05:30
|
|
|
|
2017-04-21 16:21:05 +02:00
|
|
|
#define _NMLOG2_PREFIX_NAME "pacrunner"
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
#define _NMLOG2(level, conf_id, ...) \
|
2017-04-21 16:21:05 +02:00
|
|
|
G_STMT_START \
|
|
|
|
|
{ \
|
|
|
|
|
nm_log((level), \
|
|
|
|
|
_NMLOG_DOMAIN, \
|
|
|
|
|
NULL, \
|
|
|
|
|
NULL, \
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
"%s%" G_GUINT64_FORMAT "]: " _NM_UTILS_MACRO_FIRST(__VA_ARGS__), \
|
2017-05-11 12:04:24 +02:00
|
|
|
_NMLOG2_PREFIX_NAME ": call[", \
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
(conf_id)->log_id _NM_UTILS_MACRO_REST(__VA_ARGS__)); \
|
2017-04-21 16:21:05 +02:00
|
|
|
} \
|
|
|
|
|
G_STMT_END
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
static void _call_destroy_proxy_configuration(NMPacrunnerManager *self,
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerConfId *conf_id,
|
|
|
|
|
const char *path,
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gboolean verbose_log);
|
2017-05-11 12:04:24 +02:00
|
|
|
|
|
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
static NMPacrunnerConfId *
|
|
|
|
|
conf_id_ref(NMPacrunnerConfId *conf_id)
|
2017-03-08 14:56:17 +01:00
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_assert(conf_id);
|
|
|
|
|
nm_assert(conf_id->refcount > 0);
|
2017-03-08 14:56:17 +01:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
conf_id->refcount++;
|
|
|
|
|
return conf_id;
|
2017-03-08 14:56:17 +01:00
|
|
|
}
|
|
|
|
|
|
|
|
|
|
static void
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
conf_id_unref(NMPacrunnerConfId *conf_id)
|
2017-03-08 14:56:17 +01:00
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_assert(conf_id);
|
|
|
|
|
nm_assert(conf_id->refcount > 0);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (conf_id->refcount == 1) {
|
|
|
|
|
g_variant_unref(conf_id->parameters);
|
|
|
|
|
g_free(conf_id->path);
|
|
|
|
|
c_list_unlink_stale(&conf_id->conf_id_lst);
|
|
|
|
|
g_object_unref(conf_id->self);
|
|
|
|
|
g_slice_free(NMPacrunnerConfId, conf_id);
|
2017-03-08 14:56:17 +01:00
|
|
|
} else
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
conf_id->refcount--;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
NM_AUTO_DEFINE_FCN0(NMPacrunnerConfId *, _nm_auto_unref_conf_id, conf_id_unref);
|
|
|
|
|
#define nm_auto_unref_conf_id nm_auto(_nm_auto_unref_conf_id)
|
|
|
|
|
|
2017-05-11 12:04:24 +02:00
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
static void
|
2021-08-06 15:17:05 +02:00
|
|
|
get_ip_domains(GPtrArray *domains, const NML3ConfigData *l3cd, int addr_family)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
2020-11-22 11:16:53 +01:00
|
|
|
NMDedupMultiIter ipconf_iter;
|
2021-11-09 13:28:54 +01:00
|
|
|
char *cidr;
|
2021-08-06 15:17:05 +02:00
|
|
|
guint num;
|
|
|
|
|
guint i;
|
2020-11-22 11:16:53 +01:00
|
|
|
char sbuf[NM_UTILS_INET_ADDRSTRLEN];
|
|
|
|
|
const NMPlatformIPAddress *address;
|
2021-11-09 13:28:54 +01:00
|
|
|
const NMPlatformIPRoute *route;
|
|
|
|
|
const char *const *strv;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
strv = nm_l3_config_data_get_searches(l3cd, addr_family, &num);
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
for (i = 0; i < num; i++)
|
2021-08-06 15:17:05 +02:00
|
|
|
g_ptr_array_add(domains, g_strdup(strv[i]));
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
strv = nm_l3_config_data_get_domains(l3cd, addr_family, &num);
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
for (i = 0; i < num; i++)
|
2021-08-06 15:17:05 +02:00
|
|
|
g_ptr_array_add(domains, g_strdup(strv[i]));
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
nm_l3_config_data_iter_ip_address_for_each (&ipconf_iter, l3cd, addr_family, &address) {
|
2020-11-22 11:16:53 +01:00
|
|
|
cidr = g_strdup_printf("%s/%u",
|
|
|
|
|
nm_utils_inet_ntop(addr_family, address->address_ptr, sbuf),
|
|
|
|
|
address->plen);
|
|
|
|
|
g_ptr_array_add(domains, cidr);
|
2020-09-28 16:03:33 +02:00
|
|
|
}
|
|
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
nm_l3_config_data_iter_ip_route_for_each (&ipconf_iter, l3cd, addr_family, &route) {
|
|
|
|
|
if (NM_PLATFORM_IP_ROUTE_IS_DEFAULT(route))
|
2020-11-22 11:16:53 +01:00
|
|
|
continue;
|
|
|
|
|
cidr = g_strdup_printf("%s/%u",
|
2021-08-06 15:17:05 +02:00
|
|
|
nm_utils_inet_ntop(addr_family, route->network_ptr, sbuf),
|
|
|
|
|
route->plen);
|
2020-11-22 11:16:53 +01:00
|
|
|
g_ptr_array_add(domains, cidr);
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
static GVariant *
|
2021-08-06 15:17:05 +02:00
|
|
|
_make_request_create_proxy_configuration(const char *iface, const NML3ConfigData *l3cd)
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
{
|
|
|
|
|
GVariantBuilder builder;
|
2016-08-16 05:55:57 +05:30
|
|
|
NMProxyConfigMethod method;
|
2021-11-09 13:28:54 +01:00
|
|
|
const char *s;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_variant_builder_init(&builder, G_VARIANT_TYPE_VARDICT);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (iface) {
|
|
|
|
|
g_variant_builder_add(&builder, "{sv}", "Interface", g_variant_new_string(iface));
|
|
|
|
|
}
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
method = l3cd ? nm_l3_config_data_get_proxy_method(l3cd) : NM_PROXY_CONFIG_METHOD_UNKNOWN;
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
switch (method) {
|
|
|
|
|
case NM_PROXY_CONFIG_METHOD_AUTO:
|
|
|
|
|
g_variant_builder_add(&builder, "{sv}", "Method", g_variant_new_string("auto"));
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
s = nm_l3_config_data_get_proxy_pac_url(l3cd);
|
|
|
|
|
if (s)
|
|
|
|
|
g_variant_builder_add(&builder, "{sv}", "URL", g_variant_new_string(s));
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
s = nm_l3_config_data_get_proxy_pac_script(l3cd);
|
|
|
|
|
if (s)
|
|
|
|
|
g_variant_builder_add(&builder, "{sv}", "Script", g_variant_new_string(s));
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
break;
|
2021-05-20 18:24:07 +02:00
|
|
|
case NM_PROXY_CONFIG_METHOD_UNKNOWN:
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
case NM_PROXY_CONFIG_METHOD_NONE:
|
|
|
|
|
g_variant_builder_add(&builder, "{sv}", "Method", g_variant_new_string("direct"));
|
|
|
|
|
break;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
g_variant_builder_add(
|
|
|
|
|
&builder,
|
|
|
|
|
"{sv}",
|
|
|
|
|
"BrowserOnly",
|
|
|
|
|
g_variant_new_boolean(l3cd ? !!nm_l3_config_data_get_proxy_browser_only(l3cd) : FALSE));
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
if (l3cd) {
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gs_unref_ptrarray GPtrArray *domains = NULL;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
domains = g_ptr_array_new_with_free_func(g_free);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2021-08-06 15:17:05 +02:00
|
|
|
get_ip_domains(domains, l3cd, AF_INET);
|
|
|
|
|
get_ip_domains(domains, l3cd, AF_INET6);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (domains->len > 0) {
|
|
|
|
|
g_variant_builder_add(
|
|
|
|
|
&builder,
|
|
|
|
|
"{sv}",
|
|
|
|
|
"Domains",
|
|
|
|
|
g_variant_new_strv((const char *const *) domains->pdata, domains->len));
|
|
|
|
|
}
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
return g_variant_new("(a{sv})", &builder);
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
static void
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_call_destroy_proxy_configuration_cb(GObject *source, GAsyncResult *res, gpointer user_data)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_auto_unref_conf_id NMPacrunnerConfId *conf_id = user_data;
|
2021-11-09 13:28:54 +01:00
|
|
|
gs_free_error GError *error = NULL;
|
|
|
|
|
gs_unref_variant GVariant *ret = NULL;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
ret = g_dbus_connection_call_finish(G_DBUS_CONNECTION(source), res, &error);
|
|
|
|
|
if (!ret) {
|
|
|
|
|
if (!g_error_matches(error, G_IO_ERROR, G_IO_ERROR_CANCELLED))
|
|
|
|
|
_LOG2T(conf_id, "destroy proxy configuration: failed with %s", error->message);
|
|
|
|
|
else
|
|
|
|
|
_LOG2T(conf_id, "destroy proxy configuration: cancelled");
|
|
|
|
|
return;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_LOG2T(conf_id, "destroy proxy configuration: success");
|
2017-05-11 12:04:24 +02:00
|
|
|
}
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
static void
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_call_create_proxy_configuration_cb(GObject *source, GAsyncResult *res, gpointer user_data)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_auto_unref_conf_id NMPacrunnerConfId *conf_id = user_data;
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerManager *self = NM_PACRUNNER_MANAGER(conf_id->self);
|
|
|
|
|
gs_free_error GError *error = NULL;
|
|
|
|
|
gs_unref_variant GVariant *variant = NULL;
|
|
|
|
|
const char *path = NULL;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_assert(!conf_id->path);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
variant = g_dbus_connection_call_finish(G_DBUS_CONNECTION(source), res, &error);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (!variant) {
|
|
|
|
|
if (g_error_matches(error, G_IO_ERROR, G_IO_ERROR_CANCELLED))
|
|
|
|
|
_LOG2T(conf_id, "create proxy configuration failed: %s", error->message);
|
|
|
|
|
else
|
|
|
|
|
_LOG2T(conf_id, "create proxy configuration cancelled");
|
|
|
|
|
return;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_variant_get(variant, "(&o)", &path);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (c_list_is_empty(&conf_id->conf_id_lst)) {
|
|
|
|
|
_LOG2T(conf_id,
|
|
|
|
|
"create proxy configuration succeeded (%s), but destroy it right away",
|
|
|
|
|
path);
|
|
|
|
|
_call_destroy_proxy_configuration(self, conf_id, path, FALSE);
|
|
|
|
|
} else {
|
|
|
|
|
_LOG2T(conf_id, "create proxy configuration succeeded (%s)", path);
|
|
|
|
|
conf_id->path = g_strdup(path);
|
|
|
|
|
}
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
|
|
|
|
static void
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_call_destroy_proxy_configuration(NMPacrunnerManager *self,
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerConfId *conf_id,
|
|
|
|
|
const char *path,
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gboolean verbose_log)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
2016-10-04 12:13:16 +02:00
|
|
|
NMPacrunnerManagerPrivate *priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (verbose_log)
|
|
|
|
|
_LOG2T(conf_id, "destroy proxy configuration %s...", path);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_dbus_connection_call(priv->dbus_connection,
|
|
|
|
|
PACRUNNER_DBUS_SERVICE,
|
|
|
|
|
PACRUNNER_DBUS_PATH,
|
|
|
|
|
PACRUNNER_DBUS_INTERFACE,
|
|
|
|
|
"DestroyProxyConfiguration",
|
|
|
|
|
g_variant_new("(o)", path),
|
|
|
|
|
G_VARIANT_TYPE("()"),
|
|
|
|
|
G_DBUS_CALL_FLAGS_NO_AUTO_START,
|
2022-02-18 13:36:44 +01:00
|
|
|
NM_SHUTDOWN_TIMEOUT_1500_MSEC,
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
priv->cancellable,
|
|
|
|
|
_call_destroy_proxy_configuration_cb,
|
|
|
|
|
conf_id_ref(conf_id));
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
|
|
|
|
static void
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_call_create_proxy_configuration(NMPacrunnerManager *self,
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerConfId *conf_id,
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gboolean verbose_log)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
2016-10-04 12:13:16 +02:00
|
|
|
NMPacrunnerManagerPrivate *priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (verbose_log)
|
|
|
|
|
_LOG2T(conf_id, "create proxy configuration...");
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_dbus_connection_call(priv->dbus_connection,
|
|
|
|
|
PACRUNNER_DBUS_SERVICE,
|
|
|
|
|
PACRUNNER_DBUS_PATH,
|
|
|
|
|
PACRUNNER_DBUS_INTERFACE,
|
|
|
|
|
"CreateProxyConfiguration",
|
|
|
|
|
conf_id->parameters,
|
|
|
|
|
G_VARIANT_TYPE("(o)"),
|
|
|
|
|
G_DBUS_CALL_FLAGS_NO_AUTO_START,
|
2022-02-18 13:36:44 +01:00
|
|
|
NM_SHUTDOWN_TIMEOUT_1500_MSEC,
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
priv->cancellable,
|
|
|
|
|
_call_create_proxy_configuration_cb,
|
|
|
|
|
conf_id_ref(conf_id));
|
2017-04-21 16:24:33 +02:00
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
static gboolean
|
|
|
|
|
_try_start_service_by_name(NMPacrunnerManager *self)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
NMPacrunnerManagerPrivate *priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (priv->try_start_blocked || !priv->dbus_initied)
|
|
|
|
|
return FALSE;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_LOGD("try D-Bus activating pacrunner...");
|
|
|
|
|
priv->try_start_blocked = TRUE;
|
|
|
|
|
nm_dbus_connection_call_start_service_by_name(priv->dbus_connection,
|
|
|
|
|
PACRUNNER_DBUS_SERVICE,
|
|
|
|
|
-1,
|
|
|
|
|
NULL,
|
|
|
|
|
NULL,
|
|
|
|
|
NULL);
|
|
|
|
|
return TRUE;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
/**
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
* nm_pacrunner_manager_add:
|
2016-10-04 12:13:16 +02:00
|
|
|
* @self: the #NMPacrunnerManager
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
* @iface: the iface for the connection or %NULL
|
2021-08-06 15:17:05 +02:00
|
|
|
* @l3cd: the #NML3ConfigData of the connection to extract domain info from
|
2017-04-21 15:46:56 +02:00
|
|
|
*
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
* Returns: a #NMPacrunnerConfId id. The function cannot
|
|
|
|
|
* fail and always returns a non NULL pointer. The conf-id may
|
2017-04-21 15:46:56 +02:00
|
|
|
* be used to remove the configuration later via nm_pacrunner_manager_remove().
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
* Note that the conf-id keeps the @self instance alive.
|
2016-08-16 05:55:57 +05:30
|
|
|
*/
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
NMPacrunnerConfId *
|
2021-08-06 15:17:05 +02:00
|
|
|
nm_pacrunner_manager_add(NMPacrunnerManager *self, const char *iface, const NML3ConfigData *l3cd)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
2016-10-04 12:13:16 +02:00
|
|
|
NMPacrunnerManagerPrivate *priv;
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerConfId *conf_id;
|
|
|
|
|
gs_free char *log_msg = NULL;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2017-04-21 15:46:56 +02:00
|
|
|
g_return_val_if_fail(NM_IS_PACRUNNER_MANAGER(self), NULL);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
2016-08-19 09:28:24 +02:00
|
|
|
priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
conf_id = g_slice_new(NMPacrunnerConfId);
|
|
|
|
|
*conf_id = (NMPacrunnerConfId){
|
|
|
|
|
.log_id = ++priv->log_id_counter,
|
|
|
|
|
.refcount = 1,
|
|
|
|
|
.self = g_object_ref(self),
|
2021-08-06 15:17:05 +02:00
|
|
|
.parameters = g_variant_ref_sink(_make_request_create_proxy_configuration(iface, l3cd)),
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
};
|
|
|
|
|
c_list_link_tail(&priv->conf_id_lst_head, &conf_id->conf_id_lst);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (!priv->has_name_owner) {
|
|
|
|
|
_LOG2T(conf_id,
|
|
|
|
|
"add config: %s (%s)",
|
|
|
|
|
(log_msg = g_variant_print(conf_id->parameters, FALSE)),
|
|
|
|
|
"pacrunner D-Bus service not running");
|
|
|
|
|
_try_start_service_by_name(self);
|
|
|
|
|
} else {
|
|
|
|
|
_LOG2T(conf_id,
|
|
|
|
|
"add config: %s (%s)",
|
|
|
|
|
(log_msg = g_variant_print(conf_id->parameters, FALSE)),
|
|
|
|
|
"create proxy configuration");
|
|
|
|
|
_call_create_proxy_configuration(self, conf_id, FALSE);
|
pacrunner: accept NULL interface name
Pacrunner uses the interface information to implement a myIpAddress()
function which returns the first IPv4 address of the interface
associated to a proxy. That function doesn't deal with multiple
addresses per interface, and so in case of a VPN which configures
addresses on the parent interface (e.g. IPsec), we currently pass a
NULL interface. That is correct, but triggers the following assertion:
GLib-CRITICAL **: g_variant_new_variant: assertion 'value != NULL' failed
#0 g_logv () from target:/lib64/libglib-2.0.so.0
#1 g_log () from target:/lib64/libglib-2.0.so.0
#2 g_variant_new_string () from target:/lib64/libglib-2.0.so.0
#3 nm_pacrunner_manager_send (self=0xab3230, iface=iface@entry=0x0, proxy_config=proxy_config@entry=0xc83470, ip4_config=ip4_config@entry=0x7f66b4002710, ip6_config=ip6_config@entry=0x0) at nm-pacrunner-manager.c:334
#4 _set_vpn_state (self=self@entry=0xd0c120, vpn_state=vpn_state@entry=STATE_ACTIVATED, reason=reason@entry=NM_VPN_CONNECTION_STATE_REASON_NONE, quitting=quitting@entry=0) at vpn-manager/nm-vpn-connection.c:571
#5 dispatcher_pre_up_done (call_id=<optimized out>, user_data=<optimized out>) at vpn-manager/nm-vpn-connection.c:460
#6 dispatcher_done_cb (proxy=0x988870, result=<optimized out>, user_data=0xae1740) at nm-dispatcher.c:444
Ignore the interface parameter when it's NULL.
2016-10-13 17:23:34 +02:00
|
|
|
}
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
return conf_id;
|
|
|
|
|
}
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
/**
|
|
|
|
|
* nm_pacrunner_manager_remove:
|
|
|
|
|
* @conf_id: the conf id obtained from nm_pacrunner_manager_add()
|
|
|
|
|
*/
|
|
|
|
|
void
|
|
|
|
|
nm_pacrunner_manager_remove(NMPacrunnerConfId *conf_id)
|
|
|
|
|
{
|
|
|
|
|
_nm_unused nm_auto_unref_conf_id NMPacrunnerConfId *conf_id_free = conf_id;
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerManager *self;
|
|
|
|
|
NMPacrunnerManagerPrivate *priv;
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_return_if_fail(conf_id);
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
self = conf_id->self;
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_return_if_fail(NM_IS_PACRUNNER_MANAGER(self));
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2017-04-04 11:12:53 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_LOG2T(conf_id, "removing...");
|
|
|
|
|
|
|
|
|
|
nm_assert(c_list_contains(&priv->conf_id_lst_head, &conf_id->conf_id_lst));
|
|
|
|
|
|
|
|
|
|
c_list_unlink(&conf_id->conf_id_lst);
|
|
|
|
|
|
|
|
|
|
if (!conf_id->path) {
|
|
|
|
|
/* There is no ID to destroy the configuration.
|
|
|
|
|
*
|
|
|
|
|
* That can happen because:
|
|
|
|
|
*
|
|
|
|
|
* - pacrunner D-Bus service is not running (no name owner) and we didn't call CreateProxyConfiguration.
|
|
|
|
|
* - CreateProxyConfiguration failed.
|
|
|
|
|
* - CreateProxyConfiguration is in progress.
|
|
|
|
|
*
|
|
|
|
|
* In all cases there is nothing to do. Note that if CreateProxyConfiguration is in progress
|
|
|
|
|
* it has a reference on the conf-id and it will automatically destroy the configuration
|
|
|
|
|
* when it completes.
|
|
|
|
|
*/
|
|
|
|
|
return;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
_call_destroy_proxy_configuration(self, conf_id, conf_id->path, TRUE);
|
|
|
|
|
}
|
2017-04-21 16:21:05 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gboolean
|
|
|
|
|
nm_pacrunner_manager_remove_clear(NMPacrunnerConfId **p_conf_id)
|
|
|
|
|
{
|
|
|
|
|
g_return_val_if_fail(p_conf_id, FALSE);
|
2017-04-21 15:46:56 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (!*p_conf_id)
|
|
|
|
|
return FALSE;
|
|
|
|
|
nm_pacrunner_manager_remove(g_steal_pointer(p_conf_id));
|
|
|
|
|
return TRUE;
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
/*****************************************************************************/
|
|
|
|
|
|
2016-08-16 05:55:57 +05:30
|
|
|
static void
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
name_owner_changed(NMPacrunnerManager *self, const char *name_owner)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
NMPacrunnerManagerPrivate *priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2021-11-09 13:28:54 +01:00
|
|
|
NMPacrunnerConfId *conf_id;
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gboolean has_name_owner;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
has_name_owner = (name_owner && name_owner[0]);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (priv->dbus_initied && priv->has_name_owner == has_name_owner)
|
|
|
|
|
return;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
priv->has_name_owner = has_name_owner;
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_clear_g_cancellable(&priv->cancellable);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (has_name_owner) {
|
|
|
|
|
priv->dbus_initied = TRUE;
|
|
|
|
|
priv->try_start_blocked = FALSE;
|
|
|
|
|
_LOGD("pacrunner appeared on D-Bus (%s)", name_owner);
|
|
|
|
|
priv->cancellable = g_cancellable_new();
|
|
|
|
|
c_list_for_each_entry (conf_id, &priv->conf_id_lst_head, conf_id_lst)
|
|
|
|
|
_call_create_proxy_configuration(self, conf_id, TRUE);
|
|
|
|
|
} else {
|
|
|
|
|
if (!priv->dbus_initied) {
|
|
|
|
|
priv->dbus_initied = TRUE;
|
|
|
|
|
nm_assert(!priv->try_start_blocked);
|
|
|
|
|
_LOGD("pacrunner not on D-Bus");
|
|
|
|
|
} else
|
|
|
|
|
_LOGD("pacrunner disappeared from D-Bus");
|
|
|
|
|
if (!c_list_is_empty(&priv->conf_id_lst_head)) {
|
|
|
|
|
c_list_for_each_entry (conf_id, &priv->conf_id_lst_head, conf_id_lst)
|
|
|
|
|
nm_clear_g_free(&conf_id->path);
|
|
|
|
|
_try_start_service_by_name(self);
|
|
|
|
|
}
|
|
|
|
|
}
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
static void
|
|
|
|
|
name_owner_changed_cb(GDBusConnection *connection,
|
2021-11-09 13:28:54 +01:00
|
|
|
const char *sender_name,
|
|
|
|
|
const char *object_path,
|
|
|
|
|
const char *interface_name,
|
|
|
|
|
const char *signal_name,
|
|
|
|
|
GVariant *parameters,
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
gpointer user_data)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
const char *new_owner;
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (!g_variant_is_of_type(parameters, G_VARIANT_TYPE("(sss)")))
|
|
|
|
|
return;
|
2017-04-21 15:46:56 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
g_variant_get(parameters, "(&s&s&s)", NULL, NULL, &new_owner);
|
2017-05-11 12:04:24 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
name_owner_changed(user_data, new_owner);
|
2017-04-21 15:46:56 +02:00
|
|
|
}
|
|
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
static void
|
|
|
|
|
get_name_owner_cb(const char *name_owner, GError *error, gpointer user_data)
|
2017-04-21 15:46:56 +02:00
|
|
|
{
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (!name_owner && g_error_matches(error, G_IO_ERROR, G_IO_ERROR_CANCELLED))
|
|
|
|
|
return;
|
2017-04-21 15:46:56 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
name_owner_changed(user_data, name_owner);
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
2016-10-04 11:58:32 +02:00
|
|
|
/*****************************************************************************/
|
2016-08-16 05:55:57 +05:30
|
|
|
|
|
|
|
|
static void
|
2016-10-04 12:13:16 +02:00
|
|
|
nm_pacrunner_manager_init(NMPacrunnerManager *self)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
2016-10-04 12:13:16 +02:00
|
|
|
NMPacrunnerManagerPrivate *priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(self);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
c_list_init(&priv->conf_id_lst_head);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
priv->dbus_connection = nm_g_object_ref(NM_MAIN_DBUS_CONNECTION_GET);
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
if (!priv->dbus_connection) {
|
|
|
|
|
_LOGD("no D-Bus connection to talk to pacrunner");
|
|
|
|
|
return;
|
|
|
|
|
}
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
priv->name_owner_changed_id =
|
|
|
|
|
nm_dbus_connection_signal_subscribe_name_owner_changed(priv->dbus_connection,
|
|
|
|
|
PACRUNNER_DBUS_SERVICE,
|
|
|
|
|
name_owner_changed_cb,
|
|
|
|
|
self,
|
|
|
|
|
NULL);
|
|
|
|
|
priv->cancellable = g_cancellable_new();
|
2020-09-28 16:03:33 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_dbus_connection_call_get_name_owner(priv->dbus_connection,
|
|
|
|
|
PACRUNNER_DBUS_SERVICE,
|
|
|
|
|
-1,
|
|
|
|
|
priv->cancellable,
|
|
|
|
|
get_name_owner_cb,
|
|
|
|
|
self);
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
|
|
|
|
static void
|
|
|
|
|
dispose(GObject *object)
|
|
|
|
|
{
|
2020-02-14 10:50:25 +01:00
|
|
|
NMPacrunnerManagerPrivate *priv = NM_PACRUNNER_MANAGER_GET_PRIVATE(object);
|
2017-05-11 12:04:24 +02:00
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_assert(c_list_is_empty(&priv->conf_id_lst_head));
|
2017-05-11 12:04:24 +02:00
|
|
|
|
|
|
|
|
/* we cancel all pending operations. Note that pacrunner automatically
|
|
|
|
|
* removes all configuration once NetworkManager disconnects from
|
|
|
|
|
* the bus -- which happens soon after we destroy the pacrunner manager.
|
|
|
|
|
*/
|
|
|
|
|
nm_clear_g_cancellable(&priv->cancellable);
|
2016-08-16 05:55:57 +05:30
|
|
|
|
pacrunner: refactor pacrunner to use GDBusConnection
- use GDBusConnection instead of GDBusProxy.
- rename "call-id" to "conf-id". It's really not a "call" but
configuration that gets added and NMPacrunnerManager ensures that
the configuration is send to pacrunner.
- let "conf-id" keep a reference to NMPacrunnerManager. For one,
when we remove configurations we need to call DestroyProxyConfiguration
to remove it again. We cannot just abort the requests but must linger
around until our configuration is properly cleaned up. Hence, we
anyway cannot destroy the NMPacrunnerManager earlier.
With respect to fixing shutdown not to leak anything, this merely
means that we must wait (and iterate the main loop) as long as
NMPacrunnerManager singleton still exits (that is anyway the plan
how to fix shutdown).
With these considerations it's also clear that our D-Bus calls must
have a stricter timeout: NM_SHUTDOWN_TIMEOUT_MS.
This is also nice because nm_pacrunner_manager_remove() no longer
needs a manager parameter, it can just rely on having a reference
to the manager.
- for logging the configuration IDs, don't log pointer values.
Logging pointer values should be avoided as it defeats ASLR.
Instead, give them a "log_id" number.
- pacrunner is a D-Bus activatable service. D-Bus activatable services
needs special care. We don't want to start it over and over again.
Instead, we only try to "StartServiceByName" if
- we have any configuration to add
- if pacrunner is currently confirmed not to be running (by watching
name owner changes)
- we didn't try to start it already. That means, only start it
at the beginning and afterwards set a flag to block it. When
we see pacrunner appear on D-Bus we always clear that flag,
that means if pacrunner drops of, we will try to restart it
(once).
2019-05-05 09:51:09 +02:00
|
|
|
nm_clear_g_dbus_connection_signal(priv->dbus_connection, &priv->name_owner_changed_id);
|
|
|
|
|
g_clear_object(&priv->dbus_connection);
|
2016-08-16 05:55:57 +05:30
|
|
|
|
2016-10-04 12:13:16 +02:00
|
|
|
G_OBJECT_CLASS(nm_pacrunner_manager_parent_class)->dispose(object);
|
2016-08-16 05:55:57 +05:30
|
|
|
}
|
|
|
|
|
|
|
|
|
|
static void
|
2016-10-04 12:13:16 +02:00
|
|
|
nm_pacrunner_manager_class_init(NMPacrunnerManagerClass *klass)
|
2016-08-16 05:55:57 +05:30
|
|
|
{
|
|
|
|
|
GObjectClass *object_class = G_OBJECT_CLASS(klass);
|
|
|
|
|
|
|
|
|
|
object_class->dispose = dispose;
|
|
|
|
|
}
|